Model
|
TR1512-120-60
|
|
AC Nominal Input Voltage
|
120 Vac
|
|
Maximum AC Input Voltage
|
140 Vrms
|
|
AC Input Low Transfer Voltage
(wide/narrow)
|
65/95 Vac
|
|
Frequency: (± 0.04% Crystal controlled)
|
60 Hz
|
|
Narrow Setting (Charge & Pass -
through)
|
55-64 Hz
|
|
Wide Setting (Charge)
|
55-68 Hz
|
|
Wide Setting (Pass-through)
|
41-68 Hz
|
|
Maximum AC Input Current
Pass-through
Charging
|
50 Aac
30 Aac
20 Aac
|
|
Nominal AC Input Currentb
Pass-through
Charging
|
40 Aac
28 Aac
12 Aac
|
|
Continuous Power (@ 25°C)
|
1500 VA
|
|
AC Current at Max. Charge Ratec
|
11.20 Aac
|
|
Rated Output Current
|
12.5 amps AC
|
|
Typical Efficiency
|
90%
|
|
AC Output Voltage (rms)
|
120 Vac
|
|
Max. Output Overcurrent Protection
|
30 amps AC
|
|
Overload 10 sec Rating
|
3000 VA
|
|
Short Circuit 10 sec Rating
|
50±5 Apk
|
|
DC Current at Rated Power
|
157 amps
|
|
DC Input Voltage (nominal)d
|
12.6 Vdc
|
|
DC Input Voltage Range
|
11.0-15.0 Vdc
|
|
DC Charger Rate (Adjustable) ±6%
|
10 to 70 amps
|
|
Power Factor while Charging
|
0.88
|
|
Tare Loss
|
26 W
|
|
Voltage Regulation (max.)
|
104-127 Vac
|
|
Voltage Regulation (Typical)
|
108-125 Vac
|
|
Waveform
|
modified sine wave
|
|
Load Power Factor (allowed)
|
0.8 to 1.0 (leading or lagging)
|
|
Adjustable Load Sensing Range
|
5 watts minimum to 240 watts maximum
|
|
Force Air Cooling
|
Variable speed fan
|
|
Automatic Transfer Relay
|
30 amps maximum (non-continuous)
|
|
Rated Temperature Range
|
Invert Mode: 32 °F to 122 °F (0 °C to +50 °C)
|
|
Rated Temperature Range
|
Charge Mode: 32 °F to 104 °F (0 °C to +40 °C)
105 °F to 122 °F (+40.5 °C to +50 °C) 50% derating
|
|
Storage
|
-67 °F to 167 °F (-55 °C to +75 °C)
|
|
Operating
|
15,000 feet (4570 m)
|
|
Non-operating
|
50,000 feet (16800 m)
|
|
Mounting
|
wall-mount with 16 in. (40.6 cm) mounting centers
|