Rating
|
Nominal Battery Voltages 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)
|
|
|
Maximum Solar Array STC Nameplate FLEXmax 80 12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC Systems 6250 Watts
|
|
|
NEC Recommended Solar Array STC Nameplate FLEXmax 80 12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts
|
|
|
PV Open Circuit Voltage (VOC) 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum
|
|
|
Standby Power Consumption Less than 1 Watt typical
|
|
|
Power Conversion Efficiency - Typical FLEXmax Charging Regulation Five Stages: Bulk, Absorption, Float, Silent and Equalization
|
|
|
Equalization Charging Programmable Voltage Setpoint and Duration - Automatic Termination when completed
|
|
|
Battery Temperature Compensation Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell
|
|
Charge
|
Voltage Step-Down Capability Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input
|
|
|
Programmable Auxilary Control Output 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC)
|
|
|
Status Display 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
|
|
|
Remote Display and Controller Optional Mate or Mate2 with RS232 Serial Communications Port
|
|
Cabling
|
Network Cabling Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
|
|
|
Data Logging Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage
|
|
|
Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production
|
|
|
Hydro Turbine Applications Consult factory for approved Turbines
|
|
|
Positive Ground Applications Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 cannot be used in positive ground applications)
|
|
Temperature
|
Operating Temperature Range Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C)
|
|
Other
|
Environmental Rating Indoor Type 1 (IP 30)
|
|
|
Conduit Knockouts One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom
|